picto Alfea Hybrid Duo Oil A.I.
Hybrid heat pumps Alfea Hybrid Duo Oil A.I.
picto Alfea Hybrid Duo Oil A.I.

Split air-to-water heat pump with built-in oil burner (heating + DHW)

6 models from 6 to 14 kW with 23 kW burner 
4 models from 11 to 14 kW with 29 kW burner

Alfea Hybrid Duo Oil A.I. is a hybrid heat pump solution for renovation projects, equipped with 2 zones kit, room control, optional  Boiler connection kit and an optional cooling kit. 

 

PRODUCT BENEFITS :

> Multi-energy solution for an optimum comfort even in conditions of very cold weather
> Possibility of remote piloting via Cozytouch application due to NAVISTEM 400S control system
> Energy savings due to new controls with energy input option
> 2 burners integrated: 23 kW and 29 kW

 


How to choose your Heat pump
Atlantic gives you the key information you need in order to select the heat pump corresponding to your exact need.
choice guide heat pumps
Read more about how to choose your heat pump
Heat pumps working principle
Understanding how they work
Learn more about it
pictoPRODUCT DESCRIPTION

> Solution for renovation projects

> Flow temperature of up to 80°C

> 6 models from 6 to 14 kW with 23 kW burner

> 4 models from 11 to 14 kW with 29 kW burner

> Single-phase or three-phase models

AVAILABLE OPTIONS

> 2 zones kit

> Room controller

> Boiler connection kit (optional)

> Cooling kit (optional)

picto Technical Data

ENERGY EFFICIENCY CHARACTERISTICS - HEATING - AVERAGE CLIMAT
Energy class - Heating (35°C/55°C)A++ / A+
Thermal power - heat pump (55°C)kW5 / 5
Annual energy consumption - Heating (55°C)kWh2505 / 3180
Seasonal energy efficiency - Heating (55°C)%169 / 115
Seasonal energy efficiency - Heating (55°C) with outdoor sensor%171 / 117
Sound power level (indoor/outdoor)dB(A)48 / 63
ENERGY EFFICIENCY CHARACTERISTICS - DHW - AVERAGE CLIMAT
Declared load profileL
Energy class - DHWA+
Annual energy consumption - DHWkWh880
Seasonal energy efficiency (%) - DHW%120
MAIN CHARACTERISTICS
SCOP 35 °C / 55 °C4.3 / 2.95
Heating capacity +7°C/+35°C - Underfloor HeatingkW6.00
COP +7°C/+35°C4.26
Heating capacity -7°C/+35°C - Underfloor HeatingkW4.60
COP -7°C /+35°C2.64
Heating capacity +7°C/+45°C - Low T° radiatorskW5.10
COP +7°C/+55°C2.18
Heating capacity -7°C/+45°C - Low T° radiatorskW4.45
COP -7°C/+45°C2.18
Nominal thermal power of oil back-upkW23.00
INDOOR HYDRAULIC MODULE
Noise level on Thermodynamic modedB(A)40
Dim. chimney version h x w x dmm1880x680x1206
Dim. room sealed system version h x w x dmm1200x1710x1206
Net weight/filled weightkg299/586
HYDRAULIC CHARACTERISTICS
Combustion chamber capacityL63
Max working pressurebar3
Expansion vessel capacityL18
DHW tank capacityL190
ELECTRICAL CONNECTIONS
Power supplyV/Hz230 / 50
Standby mode consumptionW0.15
HYDRAULIC CONNECTIONS
Ø Heating circ. inlet and outlet"/mm1" / 26x34
Ø DHW circ. inlet and outlet (male thread)"/mm3/4" / 20x27
CHIMNEY CONNECTION DEPENDING ON MODEL
Ø Chimney inlet and outletmm80
Burner optimum depressionPa15
ROOM SEALED SYSTEM CONNECTION DEPENDING ON MODEL
Ø Pipemm80 / 125
OPERATING RANGE
Min./max. hot/cold outdoor temperature (heat pump)°C-25/35
Heating flow water max T°°C80
Max water T°(heat pump)°C60
OUTDOOR UNIT
Noise leveldB(A)41
Operating weightkg41
REFRIGERANT CHARACTERISTICS
R410A factory loadg1100
Quantity of refrigerant in tons of CO2 equivalent2.2957
Min./max. lengthm5 /30
Max. difference in heightm20