> Suitable for new build and renovation
> 8 models: 11 to 17 kW
> Single-phase or three-phase models
> Heating only
> Patented coaxial heat exchanger
> Inverter regulation
> Integrated buffer tank 16 L (24 L for HP models)
AVAILABLE OPTIONS
> 2 zones kit (plug-and-play kit)
> Cooling kit
> Separate hot water tank
> Boiler connection kit
> Room controller
Model :
ENERGY EFFICIENCY & ACOUSTIC CHARACTERISTICS | ||
Energy class - Heating (35°C/55°C) | A++ / A++ | |
Rated heat power (35°C/55°C) | kW | 16 / 14 |
Annual energy consumption - Heating (35°C/55°C) | kWh | 8014/8757 |
Seasonal energy efficiency - Heating (35°C/55°C) | % | 163 / 125 |
Seasonal energy efficiency - Heating (35°C/55°C) with outdoor sensor | % | 165 / 127 |
Sound power level (indoor/outdoor) | dB(A) | 45 / 67 |
MAIN CHARACTERISTICS | ||
SCOP 35 °C / 55 °C | 4.25 / 3.21 | |
Heating capacity +7°C/+35°C – Underfloor Heating | kW | 16.00 |
COP +7°C/+35°C - Underfloor Heating | 4.15 | |
Heating capacity -7°C/+35°C – Underfloor Heating | kW | 14.50 |
COP -7°C/+35°C - Underfloor Heating | 5.27 | |
Heating capacity +7°C/+55°C – Radiators | kW | 14.50 |
COP +7°C/+55°C – Radiators | 2.60 | |
Heating capacity -7°C/+55°C – Radiators | kW | 10.90 |
COP -7°C/+55°C – Radiators | 1.85 | |
Heating capacity -7°C / +60°C - Radiators | kW | 10.80 |
Additional adjustable electric back-up heater | kW | 6 |
INDOOR HYDRAULIC MODULE | ||
Noise level | dB(A) | 37 |
Net weight/filled weight | kg | 53 / 75 |
Power supply | V/Hz | 230 / 50 |
OUTDOOR UNIT | ||
Noise level | dB (A) | 45 |
Operating weight | kg | 137 |
REFRIGERANT CHARACTERISTICS | ||
Min./max. length | m | 5 / 30 |
Max. difference in height | m | 15 |
R410A factory load | g | 3800 |
Quantity of refrigerant in tons of CO₂ equivalent | t | 8 |