picto Loria R32 - NEW
picto Loria R32 - NEW

Energy-efficient solution for new build projects

4 models: 4 to 10 kW
Refrigerant : R32

Loria R32 is a performing heat pump working with outside temperature from -20°C to +35°C, equipped with Magnetic mud filter which captures impurities in the heating circuit. 

The R32 refrigerant brings more efficency and performance to the Loria R32 range. Its optimised design fits all size of rooms, even small spaces. 

 

PRODUCT BENEFITS :

> Space-saving indoor hydraulic module with plate heat exchanger
> Compact solution for new build projects 
> NAVISTEM 100H regulator 
Atlantic Smart Adapt: operations without an outdoor sensor
Integrated electric back-up heater
> Anti-corrosion
> Compatible with thermostats (Wi-Fi connected or not)

 


How to choose your Heat pump
Atlantic gives you the key information you need in order to select the heat pump corresponding to your exact need.
choice guide heat pumps
Read more about how to choose your heat pump
Heat pumps working principle
Understanding how they work
Learn more about it
pictoPRODUCT DESCRIPTION

> Energy-efficient solution for new build projects

> 4 models: 4 to 10 kW

> R32 refrigerant fluid : better performances and economy

> Single-phase models

> Navistem 100H control system

> Integrated electric back-up heater

> Full Inverter regulation

AVAILABLE OPTIONS

> Magnetic mud filter

> 2 zones kit (plug-and-play kit)

> Cooling kit

> Separate hot water tank

> Room controller

picto Technical Data

ENERGY EFFICIENCY CHARACTERISTICS
Energy class - Heating (35°C/55°C)A+++ / A++
Rated heat output (35°C/55°C)kW5 / 5
Annual energy consumption - Heating (35°C/55°C)kWh2418 / 3018
Seasonal energy efficiency - Heating (35°C/55°C)%182 / 128
Seasonal energy efficiency - Heating (35°C/55°C) with outdoor sensor%184 /130
Sound power level (indoor/outdoor)dB(A)40 / 57
MAIN CHARACTERISTICS
SCOP 35 °C / 55 °C4.61 / 3.29
Heating capacity +7°C/+35°C – Underfloor heatingkW4.60
COP +7°C/+35°C - Underfloor heating4.83
Heating capacity -7°C/+35°C – Underfloor heatingkW4.50
Power consumption -7°C/+35°C - Underfloor heatingkW1.53
COP -7°C/+35°C - Underfloor heating2.94
Heating capacity +7°C/+45°C – Low T°radiatorskWTBC
COP +7°C/+45°C – Low T°radiatorsTBC
Heating capacity -7°C/+45°C – Low T°radiatorskWTBC
COP -7°C/+45°C – Low T°radiatorTBC
Heating capacity +7°C/+55°C – Low T°radiatorskW4.50
COP +7°C/+55°C – Low T°radiators2.72
Heating capacity -7°C/+55°C – Low T°radiatorskW3.90
COP -7°C/+55°C – Low T°radiators1.91
Electric back-up heaterkW3
INDOOR HYDRAULIC MODULE
Noise leveldB(A)32
Net weight/filled weightkg42 / 46
Min./Max. outdoor temperature for heating°C-20 / +35
Power supplyV / Hz230 / 50
OUTDOOR UNIT
Noise leveldB(A)35
Operating weightkg39
REFRIGERANT CHARACTERISTICS
Min./max. lengthm3 / 30
Max. difference in heightm20
R32 factory loadg970
Quantity of refrigerant in tons of CO2 equivalentt1