picto Loria
picto Loria

 Energy-efficient solution for new build projects

4 models: 4 to 10 kW
Refrigerant : R410A

Loria is a performing heat pump working with outside temperature from -20°C to +35°C, equipped with Magnetic mud filter which captures impurities in the heating circuit. 

 

PRODUCT BENEFITS :

> Space-saving indoor hydraulic module with plate heat exchanger
> One or two heating zone(s) management
> Compact solution for new build projects
> COP up to 4.80 (+7°/+35°) 
> NAVISTEM 100H regulator 
Integrated electric back-up heater
> Anti-corrosion

 


How to choose your Heat pump
Atlantic gives you the key information you need in order to select the heat pump corresponding to your exact need.
choice guide heat pumps
Read more about how to choose your heat pump
Heat pumps working principle
Understanding how they work
image_alt
Learn more about it
pictoPRODUCT DESCRIPTION

> Energy-efficient solution for new build projects

> 4 models: 4 to 10 kW

> Single-phase models

> Navistem 100H control system

> Integrated electric back-up heater

> Inverter regulation

AVAILABLE OPTIONS

> Magnetic mud filter

> 2 zones kit (plug-and-play kit)

> Cooling kit

> Separate hot water tank

> Room controller

picto Technical Data

ENERGY EFFICIENCY CHARACTERISTICS
Energy class - Heating (35°C/55°C)A+++ / A++
Rated heat output (35°C/55°C)kW4/4
Annual energy consumption - Heating (35°C/55°C)kWh1884 / 2708
Seasonal energy efficiency - Heating (35°C/55°C)%181/127
Seasonal energy efficiency - Heating (35°C/55°C) with outdoor sensor%183/129
Sound power level (indoor/outdoor)dB(A)44 / 62
MAIN CHARACTERISTICS
SCOP 35 °C / 55 °C4.6 / 3.25
Heating capacity +7°C/+35°C – Underfloor HeatingkW4.00
COP +7°C/+35°C - Underfloor Heating4.80
Heating capacity -7°C/+35°C – Underfloor Heating kkW4.10
Power consumption -7°C/+35°C - Underfloor HeatingkW1.46
COP -7°C/+35°C - Underfloor Heating2.80
Heating capacity +7°C/+45°C – Low T°radiatorskW4.00
COP +7°C/+45°C – Low T°radiators3.50
Heating capacity -7°C/+45°C – Low T°radiatorskW4.10
COP -7°C/+45°C – Low T°radiator2.30
Heating capacity +7°C/+55°C – Low T°radiatorskW3.68
COP +7°C/+55°C – Low T°radiators2.65
Heating capacity -7°C/+55°C – Low T°radiatorskW3.72
COP -7°C/+55°C – Low T°radiators1.90
Electric back-up heaterkW3
INDOOR HYDRAULIC MODULE
Noise leveldB(A)36
Net weight/filled weightkg37.5 / 41.5
Min./Max. outdoor temperature for heating°C-20 / +35
Power supplyV / Hz230 / 50
OUTDOOR UNIT
Noise leveldB(A)42
Operating weightkg41
REFRIGERANT CHARACTERISTICS
Min./max. lengthm5/30
Max. difference in heightm20
R410A factory loadg1100
Quantity of refrigerant in tons of CO2 equivalentt2