TANK CAPACITYL100
DESIGNWALL MOUNTED
CONFIGURATIONAmbient / Ducted
TANK PROTECTIONACI Hybrid
HEATING ELEMENTSteatite
DIMENSIONS (HEIGHT x DEPTH x DEPTH)mm1234 x 522 x 538
WEIGHTkg57
ELECTRICAL CONNECTIONV/Hz230/50
TOTAL MAXIMUM POWER W1550
MAXIMAL POWER HEAT PUMPW350
POWER ELECTRIC HEATING ELEMENTW1200
HEAT PUMP WATER TEMPERATURE RANGE°C50 to 62°C
HEAT PUMP AIR TEMPERATURE RANGE°C-5 to 43°C
COEFFICIENT OF PERFORMANCE (AT AIR 7°C DUCTED, WATER WATER FROM 15°C TO 53°C) 2.47
COEFFICIENT OF PERFORMANCE (AT AIR 15°C AMBIENT, WATER WATER FROM 15°C TO 53°C) 2.75
COUSTIC POWER ErP IN DUCTED CONFIGURATION45
COUSTIC POWER ErP IN AMBIENT CONFIGURATION50
HEATING TIME AT (TEMPERATURE AIR = 7°C)H7h27
ERP ENERGY CLASSA+
CONNECTIVITY IOYES
INPUT PVYES